Champion Power Equipment
Warrior 12.5 kVa  Diesel Generator
EU flag Model: LDG12S-EU

Warrior 12.5 kVa  Diesel Generator

2 Year Limited Warranty
Rated Watts: 10000
Max Watts: 11000
Start Type: Electric
2 Year Warranty
2 Year Warranty
This product carries a 2 Year Warranty.
Electric Start
Electric Start
These generators can be started by a push button or electric key start.
Intelli-Gauge
Intelli-Gauge
Generators fitted with our Intelligauge show a real-time display of Voltage, Hertz and Running Hours.
Overload Protection
Overload Protection
To help prevent damage to the engine, Overload Protection will automatically switch the generator off when it detects that the power usage exceeds the rated wattage.
Automatic Voltage Regulator
Automatic Voltage Regulator
AVR technology provides a steady motor speed alongside excellent emissions. This creates an environmentally friendly generator with reduced noise.
Warrior 12.5 kVa  Diesel Generator
2 Year Warranty
2 Year Warranty
This product carries a 2 Year Warranty.
Electric Start
Electric Start
These generators can be started by a push button or electric key start.
Intelli-Gauge
Intelli-Gauge
Generators fitted with our Intelligauge show a real-time display of Voltage, Hertz and Running Hours.
Overload Protection
Overload Protection
To help prevent damage to the engine, Overload Protection will automatically switch the generator off when it detects that the power usage exceeds the rated wattage.
Automatic Voltage Regulator
Automatic Voltage Regulator
AVR technology provides a steady motor speed alongside excellent emissions. This creates an environmentally friendly generator with reduced noise.

This new portable standby generator is designed and engineered by Warrior, it is ideal for all sorts of applications including Domestic, Construction, Industrial & Catering.

The standby generator is the ideal product during power cuts and outages.

The auto governor generator has a steady motor speed with excellent low emission rates which in turn creates an environmentally friendly generator. The standby generator has an added bonus of having reduced noise when in use. An advanced MCU allows for easy and reliable adjustment.

The heavy-duty industrial frame design provides full protection and aids portability. It is fitted with automatic voltage control which protects the unit and provides higher efficiency. The voltage control system also helps to provide the 60ltr fuel tank achieve up to 24 hours running on a full tank (based on 50% Load). The standby generator is suitable for running power tools and lighting units etc.

The standby generator has 240v and 110v single phase output sockets. Due to the advantage of having a silent enclosure this generator has a key start facility. Smooth running is ensured via the fitting of anti-vibration mountings for minimal vibration and a soundproof canopy for reduced noise. A low oil cut out feature and fuel gauge is also featured.

kVa 12.5
Max Watts 11000
Rated Watts 10000
AC Load 1 x 32amp 220v / 2 x 16amp 220v
Phase Single
Power Factor 1
RPM 3000
Engine 954
Fuel Capacity 50 Litres
Oil Capacity 3 Litres
Start Type Electric
Low Oil Shutoff Automatic
Choke Type Automatic
Noise Level @ 7m 65 dBA
Dimensions L*W*H
(Fully Assembled)
116 x 65 x 89 cm
Weight 295 kg (650.4 lbs)
Operation at 50% >24 hours
Overload Protection
AVR
Fuel Gauge
Voltmeter
Wheels Included
Certification CE,ISO9001-2000,GS,TUV
Warranty 2 Year Limited Warranty
Name  
Warrior Diesel 11-12KW Generator Manual Download
Warrior LA290 Engine Manual Download
Associated Products

Starting vs Max vs Running Watts

Most motor-driven products that you will connect to your generator need extra watts when they start, this is known as starting watts.

The Starting Watts listed on your generator is the wattage the generator can output for an average of 6 seconds (Inverter) or 10 minutes (Open Frame Type).

Once this period is over, and if the wattage has not reduced the Overload Protection will activate and the generator will trip using the following methods circuit breaker (frame type) and flashing overload light (Inverter), if this happens the power (wattage) needs to reduced or disconnected immediately and the generator needs to be reset by stopping the generator and turning everything to the ‘OFF’ position and leaving for minimum 2 minutes (Inverter Only).

The Maximum Watts listed on your generator is the MAX watts output the generator can run at – however it is not recommended to run your generator at the  maximum watts for periods more than average 5 minutes (Inverter) and 60 minutes (Open Frame Type). Once this period is over, and if the wattage has not reduced the Overload Protection will activate and the generator will trip using the following methods circuit breaker (frame type) and flashing overload light (Inverter), if this happens the power (wattage) needs to reduced or disconnected immediately and the generator needs to be reset by stopping the generator and turning everything to the ‘OFF’ position and leaving for minimum 2 minutes. While working in the max zone on an Inverter you will have solid red overload light this is normal.