Champion Power Equipment
Warrior 6.25 kVa Diesel Generator 3 Phase - Wireless Remote
UK flag EU flag Model: LDG6500SV3WRC

Warrior 6.25 kVa Diesel Generator 3 Phase - Wireless Remote

2 Year Limited Warranty
Rated Watts: 5000
Max Watts: 5500
Start Type: Electric,Remote
2 Year Warranty
2 Year Warranty
This product carries a 2 Year Warranty.
EU Stage V Compliant
EU Stage V Compliant
This generator is EU Stage V Compliant.
Electric Start
Electric Start
These generators can be started by a push button or electric key start.
Intelli-Gauge
Intelli-Gauge
Generators fitted with our Intelligauge show a real-time display of Voltage, Hertz and Running Hours.
Overload Protection
Overload Protection
To help prevent damage to the engine, Overload Protection will automatically switch the generator off when it detects that the power usage exceeds the rated wattage.
Automatic Voltage Regulator
Automatic Voltage Regulator
AVR technology provides a steady motor speed alongside excellent emissions. This creates an environmentally friendly generator with reduced noise.
Wireless remote
Wireless remote
Now you can start and stop your Champion compatible portable generator from up to 24m away with the push of a button! Portable generators with Wireless Remote Start include a convenient remote key fob.
Warrior 6.25 kVa Diesel Generator 3 Phase - Wireless Remote Warrior 6.25 kVa Diesel Generator 3 Phase - Wireless Remote Warrior 6.25 kVa Diesel Generator 3 Phase - Wireless Remote Warrior 6.25 kVa Diesel Generator 3 Phase - Wireless Remote
2 Year Warranty
2 Year Warranty
This product carries a 2 Year Warranty.
EU Stage V Compliant
EU Stage V Compliant
This generator is EU Stage V Compliant.
Electric Start
Electric Start
These generators can be started by a push button or electric key start.
Intelli-Gauge
Intelli-Gauge
Generators fitted with our Intelligauge show a real-time display of Voltage, Hertz and Running Hours.
Overload Protection
Overload Protection
To help prevent damage to the engine, Overload Protection will automatically switch the generator off when it detects that the power usage exceeds the rated wattage.
Automatic Voltage Regulator
Automatic Voltage Regulator
AVR technology provides a steady motor speed alongside excellent emissions. This creates an environmentally friendly generator with reduced noise.
Wireless remote
Wireless remote
Now you can start and stop your Champion compatible portable generator from up to 24m away with the push of a button! Portable generators with Wireless Remote Start include a convenient remote key fob.

This new and improved Warrior model boasts increased power and a fully compliant EU5 standard engine, with a brushed copper alternator within that produces a steady motor speed.

It features a Automatic Voltage Regulator (AVR) control system to monitor the output and protect the unit against voltage fluctuations, providing a smoother sine wave.

Enclosed by a soundproof canopy, coated with a chip resistant matt finish, the durable heavy-duty industrial frame provides full protection and aids portability. This silent enclosure has the added benefit of a key start facility and smooth running is further enhanced by the addition of anti-vibration mountings.

A fully fuelled 16 litre tank could easily achieve up to 12 hours running at around 50% load, making this Warrior generator ideal for all sorts of applications such as domestic supply, construction, catering and industrial use with for example power tools & lighting units. As a standby generator it is the perfect product during power cuts and outages, and is even supplied with a Wireless Remote control allowing the operator to start up the Machine while upto 10m away, perfect for those cold mornings on site or from the comfort of your home.

Fitted with 12v battery charging outlet and with 415v Three Phase and 240v Single Phase output sockets as standard as well as a remote start function.

All data supplied on this item is referring to balanced load, if using unbalanced loads you need to check data on equipment.

Features:

  • 415v Three Phase / 240v AC load
  • Up to 12 hours run time at 50% load
  • 68 dBA at 7m
  • 3 in 1 Intelli Volt Meter
  • Remote start
  • Wheels for easy portability

Please note: When running single phase off a three phase generator you will only receive approx 30-35% of the full output power as your socket is only running off one of the three phases available.

kVa 6.25
Max Watts 5500
Rated Watts 5000
AC Load 1 x 415V 16amp / 1 x 240V 16amp
Phase Three
Power Factor 0.8
RPM 3000
Engine 186
Fuel Capacity 16 Litres
Oil Capacity 1.1 Litres
Start Type Electric,Remote
Low Oil Shutoff Automatic
Choke Type Automatic
Noise Level @ 7m 68 dBA
Dimensions L*W*H
(Fully Assembled)
89 x 59 x 73 cm
Weight 168 kg (370 lbs)
Operation at 50% >12 hours
Overload Protection
AVR
Fuel Gauge
Voltmeter
Intelligauge
Electric Start
Wireless Remote
Wheels Included
Certification CE,EU Stage V,ISO9001-2000,GS,TUV,RED
Warranty 2 Year Limited Warranty
Name  
Warrior Diesel Generator Manual Download
Warrior LA186 Engine Manual Download
Warrior LDG6500SV3WRC Brochure Download

Starting vs Max vs Running Watts

Most motor-driven products that you will connect to your generator need extra watts when they start, this is known as starting watts.

The Starting Watts listed on your generator is the wattage the generator can output for an average of 6 seconds (Inverter) or 10 minutes (Open Frame Type).

Once this period is over, and if the wattage has not reduced the Overload Protection will activate and the generator will trip using the following methods circuit breaker (frame type) and flashing overload light (Inverter), if this happens the power (wattage) needs to reduced or disconnected immediately and the generator needs to be reset by stopping the generator and turning everything to the ‘OFF’ position and leaving for minimum 2 minutes (Inverter Only).

The Maximum Watts listed on your generator is the MAX watts output the generator can run at – however it is not recommended to run your generator at the  maximum watts for periods more than average 5 minutes (Inverter) and 60 minutes (Open Frame Type). Once this period is over, and if the wattage has not reduced the Overload Protection will activate and the generator will trip using the following methods circuit breaker (frame type) and flashing overload light (Inverter), if this happens the power (wattage) needs to reduced or disconnected immediately and the generator needs to be reset by stopping the generator and turning everything to the ‘OFF’ position and leaving for minimum 2 minutes. While working in the max zone on an Inverter you will have solid red overload light this is normal.